Output Type: | Single |
---|---|
Warranty: | 2 Years |
Output Power: | 1 - 50W |
*Low price and high reliablity *105ºC Ootput capacitor *AC input power suitable for the world *High efficiency and low operation tenperature *Sofft-start current can reduce the AC input impact effecticly *With short-circuit and overload protection *Compact size,light weight *100%full-load bum-in test *Installed with EMI filter, mlnlmum wave |
||||
Specification ModelNo. | MDR-20-5 | MDR-20-12 | MDR-20-15 | MDR-20-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage range (Note:2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 4A | 1.67A | 1.34A | 1A |
output current range | 0~3A | 0~1.67A | 0~1.34A | 0~1A |
Wave and noise (Note:3) | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Inlet stability (Note:4) | ±0.2% | ±0.1% | ±0.1% | ±0.1% |
Load stability (Note:5) | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
DC output power | 20W | 20W | 20W | 20W |
Efficiency | 76% | 80% | 81% | 84% |
Adjustable range for DC voltage | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V |
AC input voltage range | 85~264VAC/120~370VDC | |||
output current | 0.55A/115 40A /230V | |||
AC rush current | 20A/115V 40A/230V | |||
Leakage current | <1mA/240VAC | |||
Overload protection | 105%-150% hiccup mode,auto-recovery | |||
Over-Voltage protection | 5.75~6.75V / 13.8~16.2V / 17.25~20.25V / 27.6~32.4V | |||
DC OK signal | 3.75~6V/50mA/ 9~13.5VmA/ 11.5~16.5V/40mA/ 18~27V/20mA | |||
Temperaut re cofficient | ±0.03%/ºC (0~50ºC) | |||
Setup,rise,hold up time | 1000ms,30ms/115VAC 50ms/230VAC 20ms/115VAC | |||
Vibration | 10~500Hz, 2G 10min,1 cycle Pariod for 60min, Each axes | |||
Withstand voltage | I/P-O/P:3Kv I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||
Insulation resistance | I/P-O/P IP/FG OP-FG:500VDC/100MΩ | |||
Working temperature and humidity | -20ºC~+70ºC,20%~90%RH | |||
Overall dimension | 22.5*90*100 mm | |||
Safety Standards | Meet UL 508,UL60950-1 requirement | |||
Electromagnetic interference | EN55011,EN55022(CISP22),EN61204-3 ClassB | |||
Harmonic current | EN61000-3-2,-3 | |||
Electromagnetic tolerance | EN6100-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3 ClassA | |||
Weight | 0.17Kgs | |||
Note: 1.The testina condition for The Paramenter is:230VAC input,rated load, 25ºC 70% RH Temperature 2.Error incude the seting error, line stability and load stability 3.Wave test:adopt in "A12"double wire for 20MHz,and 0.1 UF capacitor short-circuit for interrupt bug 4.Inlet voItage stability test:When is over load,the lowest voItage of inlet is up to the hiqhest voltaqe 5.Load stability test:the load is from 0% to 100% 6.C3,4 must be knocked down |
||||